View our full list of products here.

Contact Us
Contact us

SONOFLOW® IL.52

SONOFLOW® IL.52

The SONOFLOW IL.52 sensor is designed for precise, fast and bidirectional measurement of ultra-low flow rates. Due to its instantaneous measuring method with high repetition rates, the ultrasonic inline flow meter is suitable for quick dosing processes and for measuring pulsating flows.

More about this product

The inline flow sensor SONOFLOW IL.52 measures ultra-low flow rates. The highly accurate flow meter can be integrated into multi-product manufacturing or hybrid platforms around single-use technologies for quick dosing processes and measuring pulsating flows.

Unique Product Benefits

  • Highly accurate ultra-low flow measurement
  • Instantaneous response time
  • CIP, SIP and autoclave compatible
  • Easy data evaluation and process integration

Robust & Maintenance-Free Sensor Design

Since the sensor is integrated into devices or machines and has direct contact with the medium, the parts in contact with the medium are made of high-grade PEEK material. Thus, the inline sensor is ready for sterilization-in-place (SIP), clean-in-place (CIP), and autoclave applications. In addition, the sensor impresses with its robust design, is wear- and maintenance-free and can be fitted in any position.

Excellent Measuring Performance

The SONOFLOW IL.52 monitors ultra-low flows reliably without being affected by the color and electromagnetic characteristics of the liquid itself:

  • Reliable measuring of ultra-low flows
  • Highly accurate (with an error of +/- 1%)
  • Highly precise (with a repeatability of +/- 1%)

Tech Specs

Minimum Flow

0.5 m l/ min

Maximum Flow

3 L / min

Operating Temp. Min. / Max.

0/145°C

Accuracy

1%

4 ... 20 mA

Yes

Serial Interface

RS-485 Modbus

Frequency, 0... 20kHz, max. 5V

Yes

Switching Output

Yes

Digital Input

Yes

Real-Time Flow

Yes

Volume Dosing / Totalizer

Yes

Flow Switch

Yes

Voltage Requirements

12 … 30 VDC

Current Consumption Max.

50 mA

Integr. Processing Electronics

Yes

*

Under ideal conditions accuracy up to 1%; ABD = Air Bubble Detector, CO = Clamp-On, IL = Inline, OD = Outer Diameter